Mfr. |
Model # |
Cells per Jar |
Jar, Block, or Module VoltageV |
Low Float ChargeV |
High Float ChargeV |
Type |
LOI Rating |
Case Mtrl |
Spec Gravity |
Term Qty |
Term Location |
Term Type |
Term Initial Torque (inch-lbs) |
C&D Technologies |
4LCY- 5-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCY- 7-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCY- 9-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
4LCY-11-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
1" square post |
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C&D Technologies |
3LCY-05-P |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
3LCY-07-P |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
3LCY-09-P |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
3LCY-11-P |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
1" square post |
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C&D Technologies |
2LCY-05-P |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
2LCY-07-P |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
2LCY-09-P |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
2LCY-11-P |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.215 |
2 |
Top |
1" square post |
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mfr. |
Model # |
Cells per Jar |
Jar, Block, or Module VoltageV |
Low Float ChargeV |
High Float ChargeV |
Type |
LOI Rating |
Case Mtrl |
Spec Gravity |
Term Qty |
Term Location |
Term Type |
Term Initial Torque (inch-lbs) |
C&D Technologies |
4LCY- 5-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCY- 7-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCY- 9-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
4LCY-11-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
1" square post |
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C&D Technologies |
3LCY-05-S |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
3LCY-07-S |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
3LCY-09-S |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
3LCY-11-S |
3 |
6V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
1" square post |
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C&D Technologies |
2LCY-05-S |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
2LCY-07-S |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
L Post |
110 |
C&D Technologies |
2LCY-09-S |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
2LCY-11-S |
2 |
4V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.215 |
2 |
Top |
1" square post |
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mfr. |
Model # |
Cells per Jar |
Jar, Block, or Module VoltageV |
Low Float ChargeV |
High Float ChargeV |
Type |
LOI Rating |
Case Mtrl |
Spec Gravity |
Term Qty |
Term Location |
Term Type |
Term Initial Torque (inch-lbs) |
C&D Technologies |
4LCYC- 5-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.250 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCYC- 7-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.250 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCYC- 9-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.250 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
4LCYC-11-P |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
FR-LOI |
Polycarbonate |
1.250 |
2 |
Top |
1" square post |
110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C&D Technologies |
4LCYC- 5-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.250 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCYC- 7-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.250 |
2 |
Top |
L Post |
110 |
C&D Technologies |
4LCYC- 9-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.250 |
2 |
Top |
1" square post |
110 |
C&D Technologies |
4LCYC-11-S |
4 |
8V |
2.2V |
2.25V |
Flooded Lead Calcium |
Non-FR |
Styrene-acryllonitrile (SAN) |
1.250 |
2 |
Top |
1" square post |
110 |