Mfr ModelNo AvailabilityNotes Description
EnerSys Vb2305 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [620 WPC @15 min to 1.67vpc],[254Ah (c10), 244Ah (c8), 1.240 S.G.], 4.8"L x 10.5"W x 17.3"H (max ht), 66.4 Lbs
EnerSys Vb2306 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [744 WPC @15 min to 1.67vpc],[305Ah (c10), 292.8Ah (c8), 1.240 S.G.], 4.8"L x 10.5"W x 17.3"H (max ht), 71 Lbs
EnerSys Vb2307+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [868 WPC @15 min to 1.67vpc],[356Ah (c10), 341.6Ah (c8), 1.240 S.G.], 4.8"L x 10.5"W x 17.3"H (max ht), 75.6 Lbs
EnerSys Vb2308 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [992 WPC @15 min to 1.67vpc],[406Ah (c10), 390.4Ah (c8), 1.240 S.G.], 7.4"L x 10.5"W x 17.3"H (max ht), 101 Lbs
EnerSys Vb2309 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [1116 WPC @15 min to 1.67vpc],[457Ah (c10), 439.2Ah (c8), 1.240 S.G.], 7.4"L x 10.5"W x 17.3"H (max ht), 106 Lbs
EnerSys Vb2310+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [1240 WPC @15 min to 1.67vpc],[508Ah (c10), 488Ah (c8), 1.240 S.G.], 7.4"L x 10.5"W x 17.3"H (max ht), 111 Lbs
EnerSys Vb2311+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [1364 WPC @15 min to 1.67vpc],[559Ah (c10), 536.8Ah (c8), 1.240 S.G.], 7.4"L x 10.5"W x 17.3"H (max ht), 117 Lbs
EnerSys Vb2312 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [1488 WPC @15 min to 1.67vpc],[610Ah (c10), 585.6Ah (c8), 1.240 S.G.], 9.17"L x 10.5"W x 17.3"H (max ht), 134 Lbs
EnerSys Vb2313+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [1612 WPC @15 min to 1.67vpc],[660Ah (c10), 634.4Ah (c8), 1.240 S.G.], 9.17"L x 10.5"W x 17.3"H (max ht), 140 Lbs
EnerSys Vb2314+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [1736 WPC @15 min to 1.67vpc],[711Ah (c10), 683.2Ah (c8), 1.240 S.G.], 9.17"L x 10.5"W x 17.3"H (max ht), 144 Lbs
EnerSys Vb2408 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [1848 WPC @15 min to 1.67vpc],[800Ah (c10), 774.4Ah (c8), 1.240 S.G.], 14.7"L x 8.39"W x 21.7"H (max ht), 216 Lbs
EnerSys Vb2409 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [2079 WPC @15 min to 1.67vpc],[900Ah (c10), 872Ah (c8), 1.240 S.G.], 14.7"L x 8.39"W x 21.7"H (max ht), 226 Lbs
EnerSys Vb2410 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [2310 WPC @15 min to 1.67vpc],[1000Ah (c10), 968Ah (c8), 1.240 S.G.], 14.7"L x 8.39"W x 21.7"H (max ht), 237 Lbs
EnerSys Vb2411+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [2541 WPC @15 min to 1.67vpc],[1100Ah (c10), 1064Ah (c8), 1.240 S.G.], 14.7"L x 8.39"W x 21.7"H (max ht), 247 Lbs
EnerSys Vb2412 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [2772 WPC @15 min to 1.67vpc],[1200Ah (c10), 1160Ah (c8), 1.240 S.G.], 14.7"L x 11.7"W x 21.7"H (max ht), 310 Lbs
EnerSys Vb2413 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [3003 WPC @15 min to 1.67vpc],[1300Ah (c10), 1256Ah (c8), 1.240 S.G.], 14.7"L x 11.7"W x 21.7"H (max ht), 321 Lbs
EnerSys Vb2414 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [3234 WPC @15 min to 1.67vpc],[1400Ah (c10), 1352Ah (c8), 1.240 S.G.], 14.7"L x 11.7"W x 21.7"H (max ht), 331 Lbs
EnerSys Vb2415 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [3465 WPC @15 min to 1.67vpc],[1500Ah (c10), 1456Ah (c8), 1.240 S.G.], 14.7"L x 11.7"W x 21.7"H (max ht), 342 Lbs
EnerSys Vb2416+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [3696 WPC @15 min to 1.67vpc],[1600Ah (c10), 1552Ah (c8), 1.240 S.G.], 14.7"L x 11.7"W x 21.7"H (max ht), 353 Lbs
EnerSys Vb2417 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [3927 WPC @15 min to 1.67vpc],[1700Ah (c10), 1648Ah (c8), 1.240 S.G.], 14.7"L x 15.1"W x 21.7"H (max ht), 418 Lbs
EnerSys Vb2418 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [4158 WPC @15 min to 1.67vpc],[1800Ah (c10), 1744Ah (c8), 1.240 S.G.], 14.7"L x 15.1"W x 21.7"H (max ht), 429 Lbs
EnerSys Vb2419 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [4389 WPC @15 min to 1.67vpc],[1900Ah (c10), 1840Ah (c8), 1.240 S.G.], 14.7"L x 15.1"W x 21.7"H (max ht), 439 Lbs
EnerSys Vb2420 Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [4620 WPC @15 min to 1.67vpc],[2000Ah (c10), 1936Ah (c8), 1.240 S.G.], 14.7"L x 15.1"W x 21.7"H (max ht), 451 Lbs
EnerSys Vb2421+ Discontinued Multi-Purpose Battery, Flooded Lead Antimony, Rod-Plate, styrene-acrylonitrile (san) case, 2V with (2) Threaded Brass M10 Insert terminals [4851 WPC @15 min to 1.67vpc],[2100Ah (c10), 2032Ah (c8), 1.240 S.G.], 14.7"L x 15.1"W x 21.7"H (max ht), 461 Lbs